The R8100 is the premium, ultra-portable member of our product family. It has all the functionality and test capabilities of our industry-standard R8000 communications system analyzer, but also features an internal battery, premier ergonomics and suite of advanced features that are optional on the R8000. With the R8100, there’s absolutely no trade-off between benchtop power and total portability and the unit’s Class 3 Mil-Spec shock and vibration rating at test to its suitability for nearly any LMR test environment.
- Options Included: Tracking Generator, Cable Fault Detector, and Enhanced Spectrum Analyzer / Dual Scope.
Premium Ultra-Portable Choice Communications System Analyzer, 250 kHz-1 GHz.
The R8100 is a unique device on the market since it has all the characteristics of a communications analyzer in a truly portable package. Easy to handle, combine the navigation keys and the segmentation of the screen in “zones” which is common in the FREEDOM Communication Technologies brand.
General Features:
- Spectrum Analyzer
- Signal Generator
- Sensitive Measurement Receiver
- SINAD Meter
- Distortion Meter
- Modulation Scope
- Oscilloscope
- Frequency Error Meter
- Cable Fault Locator (optional)
- FM Deviation Meter
- AM Modulation Meter
- Receive Signal Strength Meter
- Broadband and Narrowband Power Meters
- Audio Counter
- Audio Generator
- AC / DC Voltmeters
- DMR (MOTOTRBO™) test mode (optional)
- NXDN test mode (optional)
- P25 test mode (optional)
- Options Included: Tracking Generator, Cable Fault Detector, and Enhanced Spectrum Analyzer / Dual Scope.
Accessories Included:
- Telescoping Antenna & Right Angle BNC Adapter
- Microphone
- Oscilloscope Probe
- Power Cord & AC Adapter
- Cable Fault Locator Kit (R8100 only) (3dB splitter, 50-ohm load on chain w/bolt & nut, and qty 2 12-inch BNC cables)
- Internal Lithium-Ion Battery (R8100 only)
- TNC-to-BNC Adapter (R8100 only)
- 12V to 16V Converter (R8100)
Generator (Receiver test)
- Port Protection Limit: 5W for 30 seconds
- Frequency Range: 250 kHz to 1 GHz
- Extended Frequency
- Range (Optional): 250 kHz to 3 GHz
- Frequency Resolution: 1 Hz
OUTPUT LEVEL GENERATE PORT
- Range FM: +5 to -95 dBm below 2 GHz, +5 to -95 dBm above 2 GHz
- Range AM: -1 to -95 dBm below 2 GHz, -11 to -95 dBm above 2 GHz
- Resolution: 0.1 dB
- Accuracy: ±2 dB
OUTPUT LEVEL RF I/O PORT
- Range FM: -30 to -130 dBm below 2 GHz, -40 to -130 dBm above 2 GHz
- Range AM: -36 to -130 dBm below 2 GHz, -46 to -130 dBm above 2 GHz
- Resolution: 0.1 dB
- Accuracy: ±1 dB to 1GHz; ±2dB > 1 GHz
FM MODULATION
- Deviation Accuracy: 5% of setting
- Deviation Range: 0 to 75 kHz
- Deviation Resolution: 10 Hz
- Modulation Bandwidth: 5 Hz to 20 kHz
AM MODULATION
- AM Depth Range: 0 to 90%
- Resolution: 1% of setting
- Modulation Bandwidth: 100 Hz to 10 kHz
- Accuracy: 5% of setting
MODULATION TYPES
- 1 kHz Tone, Private Line, Digital Private Line (w/ DPL (Invert), Single Tone, DTMF, Two-Tone Paging, 5/6 Tone, Paging, POCSAG, External Inputs from both a supplied microphone and BNC input.
Receiver (Transmitter test)
- Frequency Range: 250 kHz – 1 GHz (3 GHz optional)
SENSITIVITY
- Narrowband FM: 2.0 uV for 10 dB EIA SINAD
- Wideband FM: 10 uV for 10 dB EIA SINAD
- AM: 10 uV for 10 dB EIA SINAD
RF I/O PORT
- VSWR: < 1.2 to 2 GHz, ≤ 1.5 to 3 GHz
- Max Power: 50 W for 5 minutes, 150 W for 30 seconds (30 sec. on, 5 min. off)
- Absolute Max Power: 150 W
- Alarm: Internal temperature alarm
ANTENNA PORT
- Maximum Power: 0 dBm
- Alarm: +10 dBm
- IF FILTERS: 6.25 kHz, 12.5 kHz, 25 kHz, 50 kHz, 100 kHz, 200 kHz
FREQUENCY ERROR MEASUREMENT
- Type of Display: Autoranging
- Resolution: 1 Hz
FM DEVIATION MEASUREMENT
- Demodulation Range: Up to ±75 kHz
- Accuracy: ±5% plus peak residual FM
- Frequency Response: Selectable per the following:
- Low Pass Filters: 300 Hz, 3 kHz, 20 kHz
- High Pass Filters: 1 Hz, 300 Hz, 3 kHz
Demodulation
- Output Level: 6.25 kHz B/W: 2.56V / 1 kHz
- 12.5 kHz B/W: 1.28V / 1 kHz
- 25 kHz B/W: 0.64V / 1 kHz
- 50 kHz B/W: 0.32V / 1 kHz
- 100 kHz B/W: 1.6V / 10 kHz
- 200 kHz B/W: 0.8V / 10 kHz
Demodulation Output
- Amplitude Flatness: 11 Hz to 7.92 kHz ±1.25 dB, 5 Hz to 20 kHz ±2 dB
Demodulation
- Output Impedance: 100 ohms nominal
AM MODULATION MEASUREMENTS
- Demodulation Range: 0 to 100%
- Accuracy: ±5% for levels below 80%
- Frequency Response: Selectable per the following:
- Low Pass Filters: 300 Hz, 3kHz, 20kHz
- High Pass Filters: 1 Hz, 300 Hz, 3 kHz
Demodulation
- Output Level: 0.8 V peak per 10% AM Modulation
Demodulation Output
- Amplitude Flatness: 11 Hz to 7.92 kHz ±1.25 dB, 5 Hz to 20 kHz ±2 dB
- Output Impedance: 100 ohms nominal
DISTORTION METER
- Range: 1% to 20%
- Distortion Accuracy: The greater of: ±0.5% of distortion or ±10% of reading
- Input Level: 0.1 V RMS min