Altronix · Power Supplies & UPS

Altronix AL1012ULXB 12VDC 10A Power Supply/Charger Board, 115VAC Input

Part number / SKU
AL1012ULXB

Works with: Sealed lead acid or gel 12VDC standby batteries Confirmed by the manufacturer


$268.09

In stock

Warranty
Manufacturer warranty

Need project or contract pricing?

Request project pricing

Not sure it fits your system? Check compatibility

Overview

What it is and who it is for

The Altronix AL1012ULXB is an off-line power supply and charger board that converts 115VAC, 60 Hz input into a filtered, electronically regulated 12VDC output at 10 A continuous. It is UL Listed for access control system units (UL 294) and cUL Listed to CSA C22.2 No. 205-M1983.

A built-in charger maintains sealed lead acid or gel batteries and switches to standby battery automatically on AC failure with zero voltage drop. Form C contacts report AC fail, low battery and battery presence, and the output has short circuit and thermal overload protection. The board measures 4.5 x 7.25 x 1.75 in, weighs 0.75 lb and operates from 32 to 120 F.

  • Best for: 12VDC access control power where a 10 A board is mounted in an enclosure.
  • System fit: 12VDC access control and security loads; sealed lead acid or gel standby batteries (sold separately).
  • Important to know: batteries are sold separately; installation must follow the Altronix instructions, the NEC and local code.

Why teams choose it

Built for reliable networks

  • High current

    12VDC at 10 A continuous from one board.

  • Battery backup

    built-in charger with automatic, zero-drop switchover on AC failure.

  • Supervised

    Form C contacts for AC fail, low battery and battery presence.

  • Protected output

    short circuit and thermal overload protection.

Specifications

Technical specifications

General
Brand Altronix
Model AL1012ULXB
Device Type Power supply/charger board
Output Filtered and electronically regulated
Protection Short circuit and thermal overload
Battery Charger Sealed lead acid or gel batteries; automatic switchover on AC failure, zero voltage drop
AC Fail Supervision Form C contacts, 1 A at 30 VDC; 6 hour report delay selectable
Low Battery Supervision Form C contacts, 1 A at 30 VDC; reports at about 10.5 VDC
Battery Presence Supervision Form C contacts
Indicators Green AC input LED; DC output LED
Electrical
Input 115VAC, 60 Hz, 2.6 A
Input Fuse 5 A / 250V
Operating Voltage 12VDC output
Output Current 10 A continuous
Maximum Charge Current 0.7 A
Wire Size Power connections 14 AWG or larger; AC fail and low battery circuits 22 to 18 AWG
Physical
Dimensions 4.5 W x 7.25 L x 1.75 H in (114.3 x 184.2 x 44.5 mm)
Weight 0.75 lb (0.34 kg)
Environmental
Operating Temperature 32 to 120 F (0 to 49 C)
Storage Temperature -4 to 158 F (-20 to 70 C)
Relative Humidity 85 percent +/- 5 percent
Heat Output Approx. 61 BTU/hr
Listings and Approvals
Agency Approvals UL Listed for Access Control System Units (UL 294); cUL Listed to CSA C22.2 No. 205-M1983, Signal Equipment