Cambium Networks WB3665HH PTP-SYNC Unit for PTP 600 and PTP 650 TDD Synchronization

Part number / SKU
WB3665HH
  • RJ45, Cat5e
  • 56 VDC phantom from PIDU/ODU

Works with: PTP 600 Series radios, PTP 650 Series radios Confirmed by the manufacturer


$401.07

In stock

Need project or contract pricing?

Request project pricing

Not sure it fits your system? Check compatibility

Overview

What it is and who it is for

The Cambium Networks WB3665HH is the PTP-SYNC unit, an indoor synchronization unit for PTP 600 and PTP 650 Series point-to-point radios. It takes a 1 Hz or 1 PPS timing signal from a GPS module, a CMM or another synchronized timing device and passes it to the radio so collocated links align their transmit and receive frames, which reduces interference between them.

One PTP-SYNC is used per link, and up to 10 units can be daisy-chained to one timing source. It is phantom powered at 56 VDC over the PIDU/ODU cable (39 to 60 V at the unit, 1.5 W max), connects with standard Cat5e cable and RJ45 connectors, and shows power, GPS and sync activity on LEDs. The unit measures 180 x 35 x 80 mm, weighs 0.6 kg and is rated for -40 to 60 °C.

When timing is unavailable it can still keep collocated radios synchronized to each other. Links on two or more towers or rooftops need a GPS receiver or other synchronized 1 Hz source.

  • Best for: sites with several collocated PTP 600 or PTP 650 links that need TDD synchronization to limit self-interference.
  • System fit: Cambium PTP 600 and PTP 650 Series radios; timing from a GPS module, CMM or other 1 Hz / 1 PPS source.
  • Important to know: one unit is needed per link; the GPS receiver or other timing source is a separate item.

Why teams choose it

Built for reliable networks

  • TDD synchronization

    aligns transmit and receive frames of collocated PTP links.

  • Scales per site

    up to 10 units daisy-chained to one timing source.

  • No separate supply

    phantom powered at 56 VDC over the PIDU/ODU cable, 1.5 W max.

  • Wide temperature range

    rated for -40 to 60 °C including solar radiation.

Specifications

Technical specifications

General
Brand Cambium Networks
Model WB3665HH
Device Type PTP-SYNC synchronization unit
Platform PTP 600 and PTP 650 Series
Timing Input 1 Hz or 1 PPS
Timing Sources GPS module, CMM or synchronized device
Configuration One unit per link
Daisy Chain Up to 10 units per timing source
Installation Indoor
Interfaces
Ports RJ45, Cat5e
LED Indicators Power, GPS, SYNC activity
Power
Power Method 56 VDC phantom from PIDU/ODU
Operating Voltage 39 to 60 VDC at unit terminals
Power Consumption 1.5 W max
Physical
Dimensions 180 x 35 x 80 mm (7.1 x 1.4 x 3.1 in)
Weight 0.6 kg (1.32 lb)
Mounting 1U rack, wall or desktop
Environmental
Operating Temperature -40 to 60 °C (-40 to 140 °F), incl. solar radiation
Humidity Up to 95%, non-condensing
Listings and Approvals
Safety UL60950, IEC60950, EN60950, CSA-C22.2 No. 60950, CB
EMC FCC Part 15 Class A, EN 301 489-4