DMP · Intrusion & Alarm

DMP 710 Bus Splitter/Repeater Module for LX-Bus and Keypad Bus

Part number / SKU
710

Works with: XT Series control panels, XR Series control panels, XF6 Series fire control panels, DMP LX-Bus devices, DMP Keypad Bus devices Confirmed by the manufacturer


$61.01

In stock

Warranty
Manufacturer warranty

Need project or contract pricing?

Request project pricing

Not sure it fits your system? Check compatibility

Overview

What it is and who it is for

The DMP 710 is a bus splitter/repeater module that adds up to three more 12 VDC LX-Bus or Keypad Bus circuits to a DMP XT Series, XR Series or XF6 Series panel. Each branch can run up to 2,500 ft, and the total of all circuits can reach 15,000 ft.

The module operates on 8.0 to 14.5 VDC and draws 32 mA. It accepts 12 to 22 AWG wire, with 18 to 22 AWG for direct keypad bus connections, and supports up to 40 devices per 2,500 ft run with a maximum voltage drop of 2.0 VDC. All circuits are Class 2, supervised and inherently power limited. The high-impact plastic housing measures 4.5 x 2.75 x 1.75 in and mounts on a wall, a single-gang box or ring, or in a DMP enclosure on the standard 3-hole pattern. It carries CSFM and FDNY approvals and UL listings including UL 864.

  • Best for: extending LX-Bus or keypad bus wiring across larger buildings on DMP systems.
  • System fit: DMP XT Series, XR Series and XF6 Series panels; LX-Bus and Keypad Bus devices.
  • Important to know: keep at least 11.8 VDC at each device with 13.8 VDC at the panel; installation should be done by a qualified alarm technician.

Why teams choose it

Built for secure sites

  • More bus circuits

    splits into up to three additional LX-Bus or Keypad Bus circuits.

  • Long runs

    2,500 ft per branch, 15,000 ft total.

  • Low current

    32 mA module draw.

  • Fire listed

    UL 864 with CSFM and FDNY approvals.

Specifications

Technical specifications

General
Brand DMP
Model 710
Device Type Bus splitter/repeater module
Outputs Up to 3 additional 12 VDC LX-Bus or Keypad Bus circuits
Circuit Length 2,500 ft (762 m) per circuit; 15,000 ft (4,572 m) total
Devices per Circuit 40 per 2,500 ft run
Circuit Class Class 2, supervised, inherently power limited
Electrical
Operating Voltage 8.0 to 14.5 VDC
Current Draw 32 mA
Wire Gauge 12 to 22 AWG; 18 to 22 AWG for direct keypad bus
Voltage Drop 2.0 VDC max; 11.8 VDC min at devices with 13.8 VDC supply
Physical
Dimensions 4.5 x 2.75 x 1.75 in (11.4 x 7.0 x 4.5 cm)
Housing High-impact plastic
Mount Type Wall, backboard, single-gang box or ring, or DMP enclosure (3-hole pattern)
Included 710 module in universal housing, hardware pack
Listings and Approvals
Agency Approvals UL 365, 609, 864, 985, 1023, 1076, 1610, 1635; ULC ORD-C1023, ORD-C1076, S304, S545; CSFM; FDNY