Tycon TP-DCDC-4856GD-BT 802.3bt 112W PoE Injector 5Gbps 40-72VDC
- EhubAmerica SKU
- TP-DCDC-4856GD-BT
In stock
- Warranty
- Manufacturer warranty
Need project or contract pricing?
Request project pricing- Help in English, Spanish and Portuguese
- 30-day returns
Not sure it fits your system? Check compatibility
Overview
What it is and who it is for
PRODUCT OVERVIEW
Tycon TP-DCDC-4856GD-BT high-power DC-to-DC PoE injector with 40-72VDC dual inputs, IEEE 802.3bt 56VDC output up to 112W, 5Gbps data passthrough, isolated input/output, surge protection, and DIN rail mounting.
PRODUCT TYPE
PoE & Power Injectors
KEY FEATURES
• IEEE 802.3bt PoE output up to 112W
• 56VDC PoE output
• Wide 40-72VDC input range
• Dual DC inputs for primary and backup power sources
• Isolated input/output supports 48VDC and -48VDC power systems
• Data passthrough up to 5Gbps
• Integrated data-line surge protection
• Low-voltage detection stops current draw below 33.2VDC input
• Overcurrent protection with automatic recovery
• Short-circuit, reverse-voltage, and overvoltage protection
• Fanless design with natural airflow cooling
• Removable wire terminal accepts up to 12 AWG wire
• Wall or DIN rail mounting
• DIN rail adapters included
• Industrial operating temperature range from -40°C to +70°C
TECHNICAL SPECIFICATIONS
• Brand: Tycon Power
• Model: TP-DCDC-4856GD-BT
• Input Voltage: ±40-72VDC, dual inputs
• Input Current at Full Load: 3.6A at 40VDC
• Input Current at Full Load: 2.6A at 56VDC
• Input Current at Full Load: 2.0A at 72VDC
• Output Voltage: IEEE 802.3bt 56VDC
• Maximum Output Current: 2.0A
• Maximum Output Power: 112W
• Load Regulation: 5%
• Line Regulation: 1%
• Ripple and Noise: 1%
• Efficiency: Greater than 80% with 40-72VDC input
• Overvoltage Protection: 59V
• Overcurrent Protection: 110-130%, automatic recovery
• Low-Voltage Detection: Stops drawing current below 33.2VDC input
• Data Passthrough: 10/100/1000/5000Mbps
• Data Clamp Voltage: 3.3V
• ESD Protection: IEC61000-4-2, ±30kV contact and air
• EFT Protection: IEC61000-4-4, 40A (5/50µs)
• Lightning Surge Protection: IEC61000-4-5, 15A (8/20µs)
• Connections: Removable wire terminal
• Maximum Wire Size: 12 AWG
• LED Indicator: Green power LED indicates valid 802.3bt detection
• LED Indicator: Red STB LED indicates input power present with no valid 802.3bt detection
• Safety Standards: UL 1950, CSA 22.2, TUV EN60950-1
• EMC Standards: FCC Class A, EN55022 Class A
• MTBF: 123,821 hours
• Mounting: Wall mount or DIN rail
• Operating Temperature: -40°C to +70°C (-40°F to +158°F)
• Operating Humidity: 5% to 90% RH, non-condensing
• Dimensions: 140 × 150 × 40 mm (5.5 × 5.9 × 1.6 in)
• Weight: 0.6 kg (1.30 lb)
• Manufacturer-Stated Warranty: 3 years
INTENDED USE / APPLICATIONS
• 48VDC or -48VDC remote power systems
• Powering IEEE 802.3bt devices from battery-based systems
• Legacy telecom systems using -48VDC input
• PoE lighting applications
• Industrial installations requiring wall or DIN rail mounting
Specifications
Technical specifications
| General | |
|---|---|
| Model | TP-DCDC-4856GD-BT |
| Brand | Tycon |
| SKU | TP-DCDC-4856GD-BT |
| Product Type | 802.3bt PoE Injector / DCDC Converter |
| Data Passthrough | 5Gbps (10/100/1000/5000Mbps) |
| Physical | |
| Dimensions | 140 x 150 x 40 mm (5.5" x 5.9" x 1.6") |
| Weight | 0.6 kg (1.30 lb) |
| Mounting | DIN Rail (adapters included) or Wall Mount |
| Cooling | Fanless, natural air flow |
| Connector Type | Removable Wire Terminal |
| Max Wire Size | 12 AWG |
| Power & Electrical | |
| Input Voltage | 40-72 VDC (Dual Inputs, +/-48VDC compatible) |
| Output Voltage | 56 VDC (IEEE 802.3bt) |
| Output Current | 2.0 A |
| Output Power | 112 W (802.3bt) |
| Load Regulation | 5% |
| Line Regulation | 1% |
| Ripple & Noise | 1% |
| Efficiency | >80% (40-72 VDC Input) |
| Overcurrent Protection | 110-130% (Auto Recover) |
| Low Voltage Detect (LVD) | 33.2 VDC threshold |
| Protections | Short Circuit, Reverse Voltage, Over Voltage (59V) |
| MTBF | 123,821 Hours |
| Networking & Connectivity | |
| Data Protection (Pin to Pin) | 1-2, 3-6, 4-5, 7-8 |
| ESD (IEC61000-4-2) | ±30 kV contact and air |
| EFT (IEC61000-4-4) | 40 A (5/50 μs) |
| Lightning (IEC61000-4-5) | 15 A (8/20 μs) |
| Clamp Voltage | 3.3 V |
| Environmental | |
| Operating Temperature Range | -40 to +70°C |
| Compatibility | |
| Safety Standards | UL 1950, CSA 22.2, TUV EN60950-1 |
| EMC Standards | FCC Class A, EN55022 Class A |
| IEEE Standard | 802.3bt |