IURON
Iuron IU-ODN-DT42E-I-16 16-Core Fiber Optic Cassette SC LC
Lead time confirmed after order.
- Product availability confirmed before fulfillment.
- Support in English, Spanish and Portuguese.
- 30-day returns and RMA support.
Product details
PRODUCT OVERVIEW
This box is used as a termination point for the feeder cable to connect with drop cable in FTTx communication network system. It integrates fiber splicing, splitting, distribution, storage, and cable connection in one unit. Meanwhile it provides solid protection and management for the FTTx network building.
PRODUCT TYPE
Fiber
KEY FEATURES
- Total enclosed structure
- Protect and manage cable effectively
- Secured with anti-theft locking mechanism
- Standard Size, Light weight
- High Quality PC material
- Suitable for SC and LC duplex adaptor and pigtail
- Easy to operate
- Suitable for indoor use
- Work Temperature: 40 ℃ ~ +85 ℃
- Relative Humidity: ≤ 85% (+30 ℃)
- Atmospheric Pressure: 70Kpa ~ 106Kpa
- Insert Loss: ≤ 0.2dB
- UPC Return Loss: ≥ 50dB
- APC Return Loss: ≥ 60dB
- Insert and Pull out Life: ≥1000 times
- Insulation: The grounding device is insulated with the Termination box, IR≥1000m Q/500V (direct current)
- Withstand Voltage: Between the grounding device and the box body, the withstand voltage is over 3000V/Min, no breakdown and flashover.U≥3000V (direct current)
TECHNICAL SPECIFICATIONS
- Brand: Iuron
- Model: IU-ODN-DT42E-I-16
- Product Type: Fiber
- Total enclosed structure
- Protect and manage cable effectively
- Secured with anti-theft locking mechanism
- Standard Size, Light weight
- High Quality PC material
- Suitable for SC and LC duplex adaptor and pigtail
- Easy to operate
- Suitable for indoor use
- Work Temperature: 40 ℃ ~ +85 ℃
- Relative Humidity: ≤ 85% (+30 ℃)
- Atmospheric Pressure: 70Kpa ~ 106Kpa
- Insert Loss: ≤ 0.2dB
- UPC Return Loss: ≥ 50dB
- APC Return Loss: ≥ 60dB
- Insert and Pull out Life: ≥1000 times
- Insulation: The grounding device is insulated with the Termination box, IR≥1000m Q/500V (direct current)
- Withstand Voltage: Between the grounding device and the box body, the withstand voltage is over 3000V/Min, no breakdown and flashover.U≥3000V (direct current)
INTENDED USE / APPLICATIONS
- Professional networking and communications deployments
- Commercial, institutional, or industrial installations
- Use with compatible equipment according to manufacturer specifications
Need help confirming the right configuration?
Share the model, application or current system. A specialist will help you confirm compatibility.