Notifier FSP-951 Intelligent Addressable Photoelectric Smoke Detector, White
- Part number / SKU
- FSP-951
- Photoelectric smoke detector
- Photoelectric
- Addressable
- Plugs into a separate base
- 15 to 32 VDC peak
Works with: B300-6 6 in flanged low-profile base, B501-WHITE 4 in flangeless base, B224RB-WH relay base, B224BI-WH isolator base, B200S-WH intelligent sounder base, B200S-LF-WH low-frequency sounder base and 6 more models Confirmed by the manufacturer
In stock
- Warranty
- Manufacturer warranty
Free Economy shipping available at checkout
Need 5 or more? Request volume pricing
- (305) 357-6575
- 100K+ orders shipped
- 30-day returns
Need project or contract pricing?
Request project pricing- Help in English, Spanish and Portuguese
Not sure it fits your system? Check compatibility
Overview
What it is and who it is for
Why teams choose it
Built for fire alarm systems
-
Panel-set sensitivity
sensitivity is programmed from the panel and reported back continuously.
-
Low loop load
200 µA maximum average standby current at 24 VDC.
-
Duct-rated airflow
listed for air velocities from 0 to 4000 ft/min.
-
Easy service testing
magnet test switch, remote test from the panel and a walk test that blinks the address.
Specifications
Technical specifications
| Product identifiers | |
|---|---|
| SKU | FSP-951 |
| General | |
| Brand | Notifier |
| Series | FSP-951 Series |
| Model | FSP-951 |
| Device Type | Photoelectric smoke detector |
| Device Type Detail | Intelligent plug-in |
| Detection Type | Photoelectric |
| Addressing | Addressable |
| Protocol | FlashScan (FSP-951 white model is FlashScan only) |
| Address Range | 1 to 159 on FlashScan; 1 to 99 on CLIP |
| Sensitivity | 0.5% to 4.0% per foot obscuration (UL); 0.5% to 3.5% per foot (ULC) |
| Factory Setting | 1.5% nominal sensitivity for panel alarm threshold |
| Indicators | Dual bi-color LEDs, 360 degree view; blink green when addressed, steady red in alarm (FlashScan only) |
| Testing | Magnet-activated functional test switch; remote test from the panel; walk test with address display (FlashScan only) |
| Mount Type | Plugs into a separate base |
| Mount Type Detail | Base on a backbox at least 1.5 in (3.81 cm) deep |
| Color | White |
| Electrical | |
| Operating Voltage | 15 to 32 VDC peak |
| Standby Current | 200 µA max average at 24 VDC (one communication every 5 seconds, LED enabled) |
| LED Current | 4.5 mA max at 24 VDC (on) |
| Wiring | Two-wire SLC; no end-of-line resistor; T-taps permitted for Style 4 (Class B) only |
| Physical | |
| Height | 2.0 in; diameter set by base |
| Diameter with B300-6 | 6.1 in (15.6 cm) |
| Diameter with B501 | 4 in (10.2 cm) |
| Weight | 3.4 oz (96.4 g) |
| Environmental | |
| Operating Temperature | 32°F to 122°F (0°C to 50°C) |
| Relative Humidity | 10% to 93% non-condensing |
| Air Velocity | 0 to 4000 ft/min (1219.2 m/min), suitable for ducts |
| Spacing | Per NFPA 72; 30 ft (9.1 m) in low-airflow applications with smooth ceilings |
| Listings and Approvals | |
| Agency Approvals | UL/ULC Listed; FM Approved; CSFM 7272-0028:0503 |
| Standards | Designed to meet UL 268, 7th Edition |